Results of steam-water-oxygen treatment of boiler units for the 300-MW power-generating sets at the Novocherkassk State Area Power Station

Man’kina, N. ; Lysenko, E. ; Lysenko, S.

Power Technology and Engineering, 2007, Vol.41(2), pp.111-113 [Periódico revisado por pares]

Texto completo disponível

Citações Citado por
  • Título:
    Results of steam-water-oxygen treatment of boiler units for the 300-MW power-generating sets at the Novocherkassk State Area Power Station
  • Autor: Man’kina, N. ; Lysenko, E. ; Lysenko, S.
  • Assuntos: Thermoelectric power station ; boiler ; heating surface ; steam-water-oxygen reatment ; passivation ; preservation ; water-chemical regime
  • É parte de: Power Technology and Engineering, 2007, Vol.41(2), pp.111-113
  • Descrição: A steam-water-oxygen treatment, passivation, and preservation (SWOT, P, and Pr) of the internal heating surfaces of TPP-110, P-210, and P-210A boilers for the 300-MW power-generating sets have been successfully introduced at the Novocherkassk State Area Power Station (SAPS). The condition of the treated heating surfaces of the boilers while in service or on stand-by was investigated to determine the required periodicity of the SWOT, P, and Pr under the service loads and existing water-chemical regime. Specific results of the investigation are presented.