skip to main content

How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram

SCHAFER, Axel ; VAGEDES, Jan

International journal of cardiology, 2013-06, Vol.166 (1), p.15-29 [Periódico revisado por pares]

Shannon: Elsevier

Texto completo disponível

Citações Citado por
  • Título:
    How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram
  • Autor: SCHAFER, Axel ; VAGEDES, Jan
  • Assuntos: Biological and medical sciences ; Cardiology. Vascular system ; Electrocardiography - instrumentation ; Electrocardiography - standards ; Heart ; Heart Rate - physiology ; Humans ; Medical sciences ; Motor Activity - physiology ; Photoplethysmography - instrumentation ; Photoplethysmography - standards ; Pulse - standards ; Rest - physiology
  • É parte de: International journal of cardiology, 2013-06, Vol.166 (1), p.15-29
  • Notas: ObjectType-Article-2
    SourceType-Scholarly Journals-1
    ObjectType-Feature-3
    content type line 23
    ObjectType-Review-1
  • Descrição: The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV. We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography). Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
  • Editor: Shannon: Elsevier
  • Idioma: Inglês